Files
linux/drivers
Andreas Dannenberg 0cfbfde65a power: bq24257: Allow input current limit sysfs access
This patch allows reading and writing of the input current limit through
the power supply's input_current_limit sysfs property. This allows
userspace to see what charger was detected (if the D+/D- USB signal-
based charger type detection is enabled) and to re-configure the maximum
current drawn from the external supply at runtime based on system-level
knowledge or user input. Note that upon charger disconnection and
re-connection the limit configured through firmware becomes active again
(or the D+/D- USB signal-based charger detection will be run again).

Signed-off-by: Andreas Dannenberg <dannenberg@ti.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
2015-09-29 16:54:52 +02:00
..
2015-09-16 16:53:38 +02:00
2015-08-15 22:10:26 -04:00
2015-09-05 19:37:31 +02:00
2015-09-16 16:53:39 +02:00